Thread Number: 33572
/ Tag: Recent Vacuum Cleaners from past 20 years
Hoover Windtunnel 2 Pet Airflow Losses |
[Down to Last] |
Post# 365596   1/24/2017 at 19:17 (2,619 days old) by wyaple (Pickerington, OH)   |   | |
Checkrate/Likes
 
     
The first two measurements were easy to get, the last one (CFM at the nozzle) required me to build an airflow box. I think this pic should easily illustrate where and by how much CFM is lost in this machine. I think this is typical performance from an inexpensive cyclonic bag less cleaner.
From the base of the machine through the cyclones, there is a loss of 124-66 = 58 CFM. From the cyclones to the nozzle, there is a loss of 66-52 = 14 CFM. Total airflow losses from the canister base to the power nozzle (held at a 45 degree angle to the floor) is 124-52 = 72 CFM or about 58% of the original airflow. Last note: the rug plate opening is fairly typical (about 26 square inches), but CFM density is well below average, about 2.0 CFM/Sq. In. If you ever wondered if this inexpensive 12 Amp beast was capable of deep cleaning, I would argue it probably wouldn't be, even with stiff bristles on the brush roll. Bill |